LankeCMS LOGO
Other parts
Hits:15163
Catphan500
Hits:12846
astro tool 615708
Hits:11881
Schlage
Hits:11583
PRODUCTS LIST Home > Product Show
The Phantom Laboratory Magphan SMR100

Product Numbers: 2016226171926

Product description: Cylindrical and Spherical Magphans® Precise, Comprehensive Testing of MRI Scanners Magphan® Phantoms are designed to perform a wide range of precision performance evaluations of Magnetic Resonance Imaging (MRI) Scanners. The design criteria for the Magphan® phantoms are based on physicist, Dr. David Goodenough's extensive experience with MRI system evaluation and his well documented research into the quantification of image system performance tests. The test objects that make up the current Magphan® models embody two decades of scientific evaluation and field experience. The Magphan®'s patented spherical design combines precise alignment of spherical geometry with cubic geometry. As magnetic field characteristics are mapped according to spherical harmonics, natural magnetic fields extend to diagonally symmetric volumes (DSVs), or spheres. This symmetry is the reason the AAPM Task Group's Report number 6a, titled "Acceptance Testing of Magnetic Resonance Imaging Systems," stated, "The sperical shape is recommended for reasons of symmetry." Imaging performance is evaluated in the transaxial, coronal, sagittal and oblique planes by rotating the sphere. The Magphan® is also available with a conventional cylindrical housing for test groups and manufacturers who prefer the conventional cylindrical shaped phantoms. Spherical Magphan® (SMR100) is a urethane sphere composed of two hemispherical shells with an inner diameter of 20cm. · The shells are connected with a simple threaded flange connecting ring. The test cube assembly can be quickly removed without tools for greater imaging flexibility and easy access for cleaning and maintenance. Cylindrical Magphan® (SMR170) has a removable end plate for internal access. The acrylic cylinder has an outer diameter of 20cm and an inner diameter of 19cm. Tests - Summary

INTRODUCTION

Cylindrical and Spherical Magphans®
Precise, Comprehensive Testing of MRI Scanners
Magphan® Phantoms are designed to perform a wide range of precision performance evaluations of Magnetic Resonance Imaging (MRI) Scanners.

The design criteria for the Magphan® phantoms are based on physicist, Dr. David Goodenough's extensive experience with MRI system evaluation and his well documented research into the quantification of image system performance tests. The test objects that make up the current Magphan® models embody two decades of scientific evaluation and field experience.

The Magphan®'s patented spherical design combines precise alignment of spherical geometry with cubic geometry. As magnetic field characteristics are mapped according to spherical harmonics, natural magnetic fields extend to diagonally symmetric volumes (DSVs), or spheres. This symmetry is the reason the AAPM Task Group's Report number 6a, titled "Acceptance Testing of Magnetic Resonance Imaging Systems," stated, "The sperical shape is recommended for reasons of symmetry." Imaging performance is evaluated in the transaxial, coronal, sagittal and oblique planes by rotating the sphere.

The Magphan® is also available with a conventional cylindrical housing for test groups and manufacturers who prefer the conventional cylindrical shaped phantoms.

Spherical Magphan® (SMR100) is a urethane sphere composed of two hemispherical shells with an inner diameter of 20cm.

· The shells are connected with a simple threaded flange connecting ring. The test cube assembly can be quickly removed without tools for greater imaging flexibility and easy access for cleaning and maintenance.
Cylindrical Magphan® (SMR170) has a removable end plate for internal access. The acrylic cylinder has an outer diameter of 20cm and an inner diameter of 19cm.
Tests - Summary
spatial uniformity

· signal-to-noise ratio (SNR)

· spherical geometry

· in-vitro sample testing

· geometric distortion (spatial linearity)

· pixel (matrix) size verification

· scan slice width and contiguity

· verification of patient alignment system

· spatial resolution up to 11 line pairs per cm (0.45mm resolution)

· low contrast sensitivity

· T1 and T2 measurements

· evaluation of 3-dimensional volume reconstruction

Stock #

Description

SMR100

Magphan® 100 including 20cm spherical housing,
10cm test cube and case

SMR140

Magphan® 140 - 10cm sphere with support disk

SMR170

Magphan® 170 including 20cm cylindrical housing,
10cm test cube and case

SMR172

Magphan® 172 including 20cm spherical housing,
20cm cylindrical housing, 10cm test cube and cases.

 

 源自:深圳市湾边贸易有限公司
网址:http://www.coastaltrading.com.cn(中文)
web :http://www.coastbuyer.com(English)
电话:0755-8621 6601
QQ 1191737095
备注:产品价格与描述不同,具体请来电咨询!

Links: coastaltrading  |   JAPLAU  |   coast-hk  |   coastbuyer  |   coastaltrading  |  
  COASTAL TRADING INC. All rights reserved 粤ICP备11054825号-3
  Add:12042 SE Sunnyside Rd, Clackamas Oregon 97015, USA Tel: (503) 214-2838 Fax:Coastal Trading Inc.
  COASTAL TRADING INC. All rights reserved 粤ICP备11054825号-3